Kramer protocol 2000 – Kramer Electronics VS-88HD User Manual

Page 19

Advertising
background image

Kramer Protocol 2000

17

Table 7: Instruction Codes for Protocol 2000

Note: All values in the table are decimal, unless otherwise stated.

INSTRUCTION

DEFINITION FOR SPECIFIC INSTRUCTION

#

DESCRIPTION

INPUT

OUTPUT

NOTE

1

SWITCH VIDEO

Set equal to video input which is to

be switched

(0 = disconnect)

Set equal to video output which is

to be switched

(0 = to all the outputs)

2, 15

3

STORE VIDEO STATUS

Set as SETUP #

0 - to store

1 - to delete

2, 3, 15

4

RECALL VIDEO STATUS

Set as SETUP #

0

2, 3, 15

5

REQUEST STATUS OF A

VIDEO OUTPUT

Set as SETUP #

Equal to output number whose

status is reqd

4, 3

61 IDENTIFY MACHINE

1 - video machine name

2 - audio machine name

3 - video software version

4 - audio software version

5 - RS422 controller name

6 - RS422 controller version

7 - remote control name

8 - remote software version

9 - Protocol 2000 revision

0 - Request first 4 digits

1 - Request first suffix

2 - Request second suffix

3 - Request third suffix

10 - Request first prefix

11 - Request second prefix

12 - Request third prefix

13

NOTES on the above table:

NOTE 2 - These are bi-directional definitions. That is, if the switcher receives the code, it will perform the instruction; and if

the instruction is performed (due to a keystroke operation on the front panel), then these codes are sent. For example, if the

HEX code

01

85

88

83

was sent from the PC, then the switcher (machine 3) will switch input 5 to output 8. If the user switched input 1 to output 7 via

the front panel keypad, then the switcher will send HEX codes:

41

81

87

83

to the PC.

When the PC sends one of the commands in this group to the switcher, then, if the instruction is valid, the switcher replies by

sending to the PC the same four bytes that it was sent (except for the first byte, where the DESTINATION bit is set high).

NOTE 3 - SETUP # 0 is the present setting. SETUP # 1 and higher are the settings saved in the switcher's memory, (i.e. those

used for Store and Recall).

NOTE 4 - The reply to a "REQUEST" instruction is as follows: the same instruction and INPUT codes as were sent are

returned, and the OUTPUT is assigned the value of the requested parameter. The replies to instructions 10 and 11 are as per

the definitions in instructions 7 and 8 respectively. For example, if the present status of machine number 5 is breakaway

setting, then the reply to the HEX code

0B

80

80

85

would be HEX codes

4B

80

81

85

NOTE 13 - This is a request to identify the switcher/s in the system. If the OUTPUT is set as 0, and the INPUT is set as 1, 2, 5

or 7, the machine will send its name. The reply is the decimal value of the INPUT and OUTPUT. For example, for a 2216, the

reply to the request to send the audio machine name would be (HEX codes):

7D

96

90

81 (i.e. 128

dec

+ 22

dec

for 2

nd

byte, and 128

dec

+ 16

dec

for 3

rd

byte).

If the request for identification is sent with the INPUT set as 3 or 4, the appropriate machine will send its software version

number. Again, the reply would be the decimal value of the INPUT and OUTPUT - the INPUT representing the number in

front of the decimal point, and the OUTPUT representing the number after it. For example, for version 3.5, the reply to the

request to send the version number would be (HEX codes):

7D

83

85

81 (i.e. 128

dec

+ 3

dec

for 2

nd

byte, 128

dec

+ 5

dec

for 3

rd

byte).

If the OUTPUT is set as 1, then the ASCII coding of the lettering following the machine’s name is sent. For example, for the

VS-7588YC, the reply to the request to send the first suffix would be (HEX codes):

7D

D9

C3

81 (i.e. 128

dec

+ ASCII for “ Y” ; 128

dec

+ ASCII for “ C” ).

NOTE 14 - The number of inputs and outputs refers to the specific machine which is being addressed, not to the system. For

example, if six 16X16 matrices are configured to make a 48X32 system (48 inputs, 32 outputs), the reply to the HEX code

3E

82

81

82 (ie. request the number of outputs)

would be HEX codes

7E

82

90

82

ie. 16 outputs

NOTE 15 – When the OVR bit (4

th

byte) is set, then the “ video” commands have universal meaning. For example, instruction

1 (SWITCH VIDEO) will cause all units (including audio, data, etc.) to switch. Similarly, if a machine is in “ FOLLOW”

mode, it will perform any “ video” instruction.

Advertising