15

7.2 PL-8 Commands in Protocol 3000

This RS-232/RS-485 communication protocol

1

7.2.4

lets you control the machine

from any standard terminal software (for example, Windows®

HyperTerminal Application) and uses a data rate of 115200 baud, with no

parity, 8 data bits, and 1 stop bit. This section describes all commands sent to

the PL-8. For an explanation of the syntax and use of Protocol 3000, see

section

.

7.2.1

Operating Commands

Following are the specific commands that the room controller (RC device)

sends to the PL-8 to operate the external devices.

Command

Syntax

Response

Relay control

RELAY RELAY_NUM, STATE

RELAY RELAY_NUM , STATE

RESULT

Parameter Description:

RELAY_NUM = 1 to 8

STATE = Relay state:

‘0’ or ‘close’ to close the relay
‘1’ or ‘open’ to open the relay

Command

Syntax

Response

Relay status

RELAY RELAY_NUM

RELAY RELAY_NUM

RESULT

Parameter Description:

RELAY_NUM = 1 to 8

7.2.2

Identification Commands

Command

Syntax

Response

Read device model

MODEL?

MODEL MACHINE_MODEL

Read device firmware

version

VERSION?

VERSION MAJOR .MINOR .BUILD .REVISION

7.2.3

Reset Command

Command

Syntax

Response

Reset device

RESET

RESET OK

7.2.4

K-NET management commands

Command

Syntax

Response

Change KNET number

KSET NEW_K_ID

KSET NEW_K_ID RESULT

Parameter Description:

KNET_ID
"1" or "Master"
"2" … (Slave)

1 Not available at the time of printing. Refer to our Web site at http://www.kramerelectronics.com for details