4 command forms, 5 command chaining, 6 maximum string length – Kramer Electronics PL-8 User Manual

Page 21: 7 backward support, 8 technical specifications, Command forms, Command chaining, Maximum string length, Backward support, Technical specifications

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Technical Specifications

18

7.3.4

Command Forms

Some commands have short name syntax in addition to long name syntax to

allow faster typing. The response is always in long syntax.

7.3.5

Command Chaining

Multiple commands can be chained in the same string. Each command is

delimited by a pipe character ( '|' ). When chaining commands, enter the
message starting character

and the message closing character only once, at

the beginning of the string and at the end.
Commands in the string do not execute until the closing character is entered.
A separate response is sent for every command in the chain.

7.3.6

Maximum String Length

64 characters

7.3.7

Backward Support

Protocol 2000 is transparently supported by Protocol 3000. You can switch

between protocols using a switch protocol command from either platform.

8 Technical Specifications

Table 6 includes the technical specifications:

Table 6: Technical Specifications

1

INTERFACE:

of the PL-8 Low Voltage Relay Controller

RS-232 9-pin D-sub Connector
2 K-NET on terminal block connectors

OUTPUTS:

4 relays on terminal block connectors, NO: Normally Open; C: Common

Voltage; NC: Normally Closed (36V AC or DC, 2A, 60VAC maximum on
non-inductive load)

4 relays on terminal block connectors, NO: Normally Open; NC: Normally

Closed (36V AC or DC, 2A, 60VAC maximum on non-inductive load)

CONTROL:

LEDs: LINK and ON

POWER SOURCE: 12V DC 130mA

DIMENSIONS:

12.1cm x 7.18cm x 2.42cm (4.76" x 2.83" x 0.95"), W, D, H

WEIGHT:

0.3kg. (0.67lbs) approx.

ACCESSORIES:

Power supply, mounting bracket

1 Specifications are subject to change without notice