Communication Protocol

17

Byte 2 Command Description

Byte 3 (parameter value)

GLOBAL
20

OUTPUT FORMAT

0 - YUV

1 - RGB

2 - RGBS

21

OUTPUT_STANDARD

0 - PAL B

1 - PAL N

2 - PAL M

3 - NT 3

4 - NT 4

5 - SEC

22

GENLOCK

0 - OFF

1 - ON

23

PANEL_LOCK

0 - OFF

1 – ON

24

SCH

-100 - +100

24

DELAY

-100 - +100

26

FREEZE

0 - OFF

1 - ON

27

PROGRAM

0 - 15 (read only)

28 GENLOCK_STAT

(Read

only)

0 – No GENLOCK

1 – GENLOCK


Byte 4 is the machine address: can be 98 or 99 (in HEX).
First byte = I
Second byte=D
Third byte=E

MACHINE TO PC:

MACHINE

POWER-UP

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

PRESS

OF

"RECALL"

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

PRESS

OF

"STORE"

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

CHANGE

"OUTPUT_STANDARD"

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

CHANGING

OTHER

KEYS

PC <- I = 33;D = PARAMETER NUMBER; E = PARAMETER <- MACHINE (PARAMETER WRITE)

PC TO MACHINE:

RESET

VIDEO

POWER-UP(PSEUDO)

PC -> I = 0;D = 0;E = 0 -> MACHINE
PC <- I = 0;D = 0;E = 0 <- MACHINE

DEFAULT

PC -> I = 0;D = 1;E = 0 -> MACHINE
WRITE EEPROM ALL PARAMETERS - DEFAULT (ALL PROGRAMS),RELOAD (RESTART)
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

PARAMETER

READ

PC -> I = 32;D = PARAMETER NUMBER;E = 0 -> MACHINE
PC <- I = 32;D = PARAMETER NUMBER;E = PARAMETER <- PARAMETER

PARAMETER

WRITE

PC -> I = 33;D = PARAMETER NUMBER;E = PARAMETER -> MACHINE
PC -< I = 33;D = PARAMETER NUMBER;E = PARAMETER <- MACHINE

WRITE

OUTPUT_STANDARD

PC -> I = 33;D = 21;E = PARAMETER -> MACHINE MACHINE RELOAD (RESTART)
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

RECALL

PC -> I = 34;D = 0;E = PROGRAMM NUMBER -> MACHINE
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE
PROGRAMM NUMBER - 0 = PROGRAMM 1
PROGRAMM NUMBER - 1 = PROGRAMM 2
PROGRAMM NUMBER - 15 = PROGRAMM 16