Communication Protocol

18


STORE

PC -> I = 35;D = 0;E = PROGRAMM NUMBER -> MACHINE
PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

IDENTIFY

MACHINE

MACHINE

NAME

PC -> I = 61;D = 1;E = 0 -> MACHINE
PC <- I = 61;D = MACHINE NAME HIGH;E = MACHINE NAME LOW <- MACHINE

SOFTWARE

VERSION

PC -> I = 61;D = 3;E = 0 -> MACHINE
PC <- I = 61;D = SOFTWARE VERSION HIGH;E = SOFTWARE VERSION LOW <- MACHINE


Examples:
1. Select CV input format:
H21 H80 H80 H98
Unit response:
H61 H80 H80 H98
2. Reset:
H80 H80 H80 H98
3. Recall set up 1:
HA2 H80 H80 H98
DEC: 162 128 128 152
4. Store set up 2:
HA3 H80 H81 H98
DEC: 162 128 129 152