2 about the power connect™ feature, About the power connect™ feature – Kramer Electronics TP-45EDID User Manual

Page 8

Advertising
background image

TP-45EDID - Overview

5

EDID capture that copies and stores the EDID from a display device

The Power Connect™ feature where one unit can power the other over the

same CAT 5 cable

12V DC power

Toggling push-button selector switches and status LEDs connected by a

remote selector input terminal block

3.1

Shielded Twisted Pair (STP)/Unshielded Twisted Pair
(UTP)

We recommend that you use Shielded Twisted Pair (STP) cable, and stress that

the compliance to electromagnetic interference was tested using STP cable. There

are different levels of STP cable available, and we advise you to use the best

quality STP cable that you can afford.

Our non-skew-free cable, Kramer BC-STP

is intended for analog signals where skewing is not an issue.

In cases where there is skewing, our Unshielded Twisted Pair (UTP) skew-free

cable, Kramer BC-XTP, may be advantageous, and UTP cable might also be

preferable for long range applications. In any event when using UTP cable, it is

advisable to ensure that the cable is installed far away from electric cables, motors

and so on, which are prone to create electrical interference.

3.2

About the Power Connect™ Feature

The Power Connect feature applies as long as the cable can carry power. This

feature is available when using STP cable and the distance does not exceed 50m

(164ft) on standard CAT 5 cable. For longer distances, heavy gauge cable should

be used (TP cable is still suitable for the video/audio transmission, but not for

feeding the power at these distances). For units which are connected via RJ-45

connectors, make sure that the shield of the STP cable is connected to the metal

casing of the connectors on both ends of the cable. For units which are connected

via terminal block connectors, the shield of the STP cable must be connected to a

ground terminal on the units at both ends (use the ground terminal of the power

supply connection if necessary).

Advertising