Extended roof bracket installation, Roof supported installations – M&G DuraVent DuraTech® 5-8 User Manual

Page 13

Advertising
background image

13

least (2) 8-penny nails or (2) #8, 1-1/2 screws.

Do not add more Chimney Sections until

the Elbows are supported. Be sure that the

chimney remains vertical. If there is more than

one Chimney Section between the Elbows,

install a second Elbow Strap around the joint of

the two Chimney Sections (Fig 15).

EXTENDED ROOF BRACKET

INSTALLATION

If the chimney extends more than 5 feet

above the roofline, an Extended Roof Bracket

must be installed at every 5-foot increment

of chimney height above the roofline, leaving

no more than 5 feet of chimney extending

above the last pipe bracket. The Extended

Roof Bracket consists of the Pipe Band, the

Adjustable Legs, and the Roof Brackets.

1. Mount Pipe Band: Slip the Pipe Band

around the chimney and secure by tightening

the nut and bolt.

2. Attach the Legs: The Adjustable Legs

of the assembly will adjust from 67” to 114”.

Secure one end of each Leg to the Pipe Band

using the nuts and bolts included (2 per Leg).

Position the Adjustable legs so they form

approximately a 60° angle with the chimney,

and with each other (Figures 16 and 17). Be

sure that there is at least 3” of overlap between

the top and bottom halves of the Adjustable

Leg. In order to secure Legs in proper

position, there is a hole provided in the outer

leg where the outer and inner halves overlap.

Use a 1/4” drill bit to drill through the inner leg

at that location. Use the nut & bolt provided to

pin the Adjustable Legs in position.

3. Install Roof Brackets: Mount the two

Roof Brackets where each of the Adjustable

Legs meets the roof, using (4) 1” roofing nails

or screws per bracket. Seal the nail heads

carefully with a non-hardening, waterproof

sealant. Attach the bottom end of the

Adjustable Legs to the Roof Brackets using the

nuts & bolts provided.

ROOF SUPPORTED

INSTALLATIONS

There are two types of Roof Supported

Installations: (1) Using a Square Ceiling

Support Box, Reduced Clearance Support

Box, or CAS Ceiling Support; and (2) Using a

Roof Support.

(1) For a Square Ceiling Support Box,

Reduced Clearance Support Box, or CAS

Ceiling Support installation, make sure that

the square box portion of the Support Box can

extend at least 2” below the low side of the

finished ceiling (Fig 19). If the CAS Ceiling

Support is used, refer to the DuraTech CAS

Figure 16

Figure 17

PIPE BAND

AROUND

CHIMNEY

SECTION

ADJUSTABLE

LEGS ADJUST

FROM 67 TO

114 INCHES

EXTENDED ROOF

BRACKET ASSEMBLY

CHIMNEY CAP

EXTENDED ROOF

BRACKET

ADJUSTABLE LEGS

MUST USE EXT.

ROOF BRACKET IF

OVER 5 FT

Advertising