Figure 18

Figure 19

SQUARE PORTION

OF SUPPORT BOX

NEEDS A MIN OF 2

INCHES CLEARANCE TO

FINISHED CEILING

18 INCH MIN CLEARANCE

FOR SINGLE-WALL

STOVEPIPE

CAP

ADJUSTABLE

FLASHING

CHIMNEY

SECTION

STORM

COLLAR

CHIMNEY

SECTION

FRAMED

OPENING

SQUARE

CEILING

SUPPORT BOX

OR REDUCED

CLEARANCE

SUPPORT BOX

CHIMNEY

SECTION

CHIMNEY

SECTION

CAP

ADJUSTABLE

FLASHING

CHIMNEY

SECTION

STORM

COLLAR

SQUARE

CEILING

SUPPORT BOX

OR REDUCED

CLEARANCE

SUPPORT BOX

CHIMNEY

SECTION

Installation Instructions for directions on how

to install the remainder of the Combustible Air

System. The Support Box must remain level,

and the top edge of the box must cover the

edge of the roof’s decking material. Square

Ceiling Support Boxes are available in 11-inch,

24-inch, and 36-inch heights. The Reduced

Clearance Support Box is available in 24”

length for 6” diameter chimney only. Mobile

home chimney installations are roof supported.

Do not seal openings in flashing.

1. Place Appliance: Place the appliance in its

proper location, referring to the manufacturer’s

instructions as to allowable distances from

combustibles, etc.

2. Cut Openings: Cut a roof opening in your

desired location, just as in a Ceiling-Supported

Installation (Steps 1 through 5). If a separate