Offset deviation, Offset chimney, Installation instructions – M&G DuraVent DuraTech® Canada User Manual

Page 8

Advertising
background image

8

OFFSET DEVIATION

3

OFFSET CHIMNEY

If it is necessary to offset the chimney in order for it to pass through

an upstairs cupboard or to clear a joist, do this by using 15°, 30° or 45

insulated elbows. A maximum of two offsets (4 elbows in all) is allowed

in a chimney.
The minimum chimney height when using 15° offsets is 10’.
The minimum chimney height when using 30° offsets is 15’.
The maximum length of unsupported offset chimney is 6’. If the offset

chimney is longer than 6’, then it must be supported at 6’ intervals

using an offset support (DTC-RESU) or wall band (DTC-WSU). Or if a

Premium Shield is used then a Radiation Shield Connector (DTC-RSCI)

must be installed in the offset portion and attach to trusses with (2) two

plumbers straps.

INSTALLATION INSTRUCTIONS

If you are venting a Factory built fireplace or an oil or gas burning

appliance please refer to installation notes #2 (on page 5) for guidelines

on the use of the Premium shields.

For Unenclosed installation or venting of oil or gas appliances:

Put the first chimney length in the support. Turn it clockwise to lock it

in place.

Note: the male coupling must be on top.

RADIANT

SHIELD

CONNECTOR

(DTC-RSCI)

RADIANT SHIELD

CONNECTOR SUPPORT

(DTC-RSSR)

FLEXIBLE

SHIELD

(DTC-FLXS)

SWIVEL

ADAPTORS

OPTIONAL

(DTC-SA)

SPRING

SPACERS

RADIANT

SHIELD

CONNECTOR

FIRESTOP

(DTC-FRSC)

Figure 11

FLASHING COLLAR (DTC-SC)

1” MIN

Stack the next chimney length on the first length. Be sure that the male

and female threads are not in line when putting the lengths together. Turn

the chimney clockwise to lock it in place. You may add a 1/2in stainless

steel self tapping screw to prevent accidental unlocking. When you reach

the height at which the elbow will be installed:
Step 1. Install the insulated offset elbow on the vertical chimney length.

Turn it in the required direction and fasten it to the chimney with

the (4)-1/2" metal screws provided.

Step 2. Place the required offset chimney length (see chart below) on

the elbow. Turn it clockwise to lock it in place.

Step 3. Use another elbow to turn the chimney vertically. Again secure

the elbow to the chimney length using the (4)-1/2’’ metal screws.

For Enclosed installation (6", 7", and 8" dia. only)

(woodstove or coal burning appliance)

:

- Place the first chimney length on a flat surface with the male coupling

on top.

- Slide a flexible shield (DTC-FLXS) on top of that length all the way to

the bottom.

- Attach the flexible shield to the section using 3 x 1/2" stainless steel

self tapping screws.

- Slide this assembly in the support and turn clockwise to lock it in

place.

- At the ceiling level from the top, install a Radiation Shield Connector

(DTC-RSCI) and a Radiation Shield Support (DTC-FRSCS). Attach but

not tighten together yet (see Figure 13).

- Slide the Radiation Shield Connector down until the bottom of the

insulated tube exceed the bottom of ceiling.

Adjust the height until a minimum of (1”) of the Radiation Shield

Connector exceed the bottom of ceiling ( see Figure 11).

Stack the next chimney length on the first length. Be sure that the male

and female threads are not in line when putting the lengths together. Turn

the chimney clockwise to lock it in place. You may add a 1/2 in stainless

steel self tapping screw to prevent accidental unlocking.

When you reach the height at which the elbow will be installed:

Step 1. Install the insulated offset elbow on the vertical chimney length.

Turn it in the required direction and fasten it to the chimney with

the (4)-1/2’ metal screws provided.

Step 2. Place the required offset chimney length (see table 8) on the

elbow. Turn it clockwise to lock it in place.

Step 3. Use another elbow to turn the chimney vertically. Again secure

the elbow to the chimney length using the (4)-1/2" metal screws.

Attach a spacer spring around the chimney at each elbow to help keep

the flexible shield centered. (See figure 11) Slide the flexible shield up

the chimney and attach it below the ceiling to the Support Radiation Shield

using 3 self tapping metal screws. If you are limited in space to screw,

install a Swivel Adaptor (DTC-SA) (figure 11) below the Shield Connector

(DTC-RSCI) and one on the top end of the flexible shield.

In the attic:

• Fix the radiation shield to the chimney and tight the support collar.

• If the chimney is not enclosed in the attic, a storm collar (DTC-SC) must

be installed on top of Radiation Shield to prevent any loose insulation

from falling in the area between the chimney and the support.

• If the chimney is to be enclosed within the attic, continue installed

chimney sections up through the roof opening. Lower another

Telescopic Shield through the roof opening down onto the Radiation

Shield Connector.Adjust the height of the shield`s tube so it terminates

just above the roof opening but under the flashing.Once satisfied with

positioning, secure both ends of the shield using self-tapping screws.

Advertising