Minimum Enclosure Dimensions

Min.

Max.

Recommended

Height*

29”

31” **

30”

Width

36”

43” **

40”

Depth***

18”

22” ****

20”

* The enclosure height must be raised the same amount as the floor protection (e.g. if you are using 1” floor

protection, the min. height is 30” above the sub-floor).

** The maximum height is determined by the surround panel size (the surround panels are 32” tall).

*** When determining depth, include the facing material (drywall, tile, etc.) – see the illustration below.

**** When venting vertically, there is no maximum depth.

Width

Depth*

Height

When determining the position of the insert, consider

the position of the framing behind the insert relative to

the vent - see the illustration below.

* When determining the depth, include

the facing material (drywall, tile, etc.).

7.5”

Pellet vent requires 3”

clearance to combustibles.

TOP VIEW

NOTE: The enclosure may be

raised. The minimum

distance from the base of the

enclosure to the ceiling is 72”

Ceiling