INDICATORS

Incorrect polarity.

Charging process

Charging completed. Pulse maintenance.

Standby / Power on. Charger ready to use, please select charging function.

TECHNICAL DATA

Voltage AC 

 120VAC, 60Hz. Output power is reduced at lower input voltage. 
A perfect charge will still be achieved.

Current

1.1A rms

Back Current Drain* 1.3mA
Charging Voltage  

Nominal: 12V 14.4/14.7V

Ripple** 

Max 50mV rms, max 0.13A. 

Charging Current 

0.8/3.3A max

Ambient Temperature   - 4°F to +122°F. Automatic reduction of power at increased ambient 

temperature.

Cooling

Natural convection. Do not cover the charger.

Charger type  

Four step fully automatic with pulse maintenance mode.

Type of batteries

All types of lead-acid batteries.

Battery Capacity

2–90Ah

Dimensions 6

1

/

2

x 2

3

/

8

x 1

1

/

2

 inches (L x W x H) 

Enclosure 

Splashproof/Rainproof.

Weight

1.1 lbs

*) The back current drain is the current that the charger uses from the battery when the
wall plug is not connected. The reverse current of the BatteryCharger 200 is very low and
corresponds to 1Ah per month.