Installing the washer, Step 1: position washer near installation area, Step 2: connect fill hoses – Alliance Laundry Systems FLW1527C User Manual

Page 9: Warning

Advertising
background image

Installation

7

803447

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installing the Washer

Step 1: Position Washer Near Installation
Area

Move washer so that it is within 1.2 meters (4 feet) of
the desired area of installation.

NOTE: For best performance and to minimize
vibration or movement, install washer on a solid,
sturdy and level floor. Some floors may need to be
reinforced, especially on a second floor or over a
basement. Do not install the washer on carpeting,
soft tile, a platform or other weakly supported
structures.

Figure 3

Step 2: Connect Fill Hoses

Water Supply

Water supply faucets must fit standard 19.1 mm
(3/4 inch) female garden hose couplings. DO NOT
USE SLIP-ON OR CLAMP-ON CONNECTIONS.

Water supply faucets should be readily accessible to
permit turning them off when washer is not being
used.

Recommended cold water temperature is 16° to 27°
Celsius (60° to 80° Fahrenheit). Recommended
maximum hot water temperature is 51° Celsius
(125° Fahrenheit). Warm water is a mixture of hot and
cold water. Warm water temperature is dependent
upon water temperature and pressure of both the hot
and cold water supply lines.

Water pressure must be a minimum of 138 to a
maximum of 827 kPa (20 to 120 psi) static pressure
measured at the faucet.

NOTE: Water pressure under 138 kPa (20 psi) will
cause an extended fill time in the washer and may
not properly flush out the detergent dispenser.

The appliance is to be connected to the water mains
using new hose-sets and old hose-sets should not be
reused.

H054I

H054I

Under certain conditions, hydrogen gas
may be produced in a hot water system
that has not been used for two weeks or
more. HYDROGEN GAS IS EXPLOSIVE. If
the hot water system has not been used
for such a period and before using the
washer, turn on all hot water faucets and
let the water flow from each for several
minutes. This will release any
accumulated hydrogen gas. The gas is
flammable. Do not smoke or use an open
flame during this time.

W029

WARNING

To prevent personal injury, avoid contact
with inlet water temperatures higher than
51

o

Celsius (125

o

Fahrenheit) and hot

surfaces.

W750

WARNING

Advertising