6 Commissoning, operation

24

WIKA operating instructions digital indicator DI10

Menu level Parameterization level




LI-2


Limit value /Limits, LI-2:

0

0

0

0


For both limit values, two different values can be
parameterized. With this, the parameters for each limit value
are called up one after the other.




HY-2


Hysteresis for limit values, HY-2:

0

0

0

0


For both limit values, a hysteresis function exists that reacts
according to the functional principle (operating current /
quiescent current).




Fu-2


Function if display falls below / exceeds limit value, FU-2:

HIgH

Louu

(Low)


To indicate if the value falls below the lower limit value, Louu
can be selected (LOW = lower limit value) and if it goes above
the upper limit value, high can be selected (HIGH = upper limit
value). LOW corresponds to the quiescent current principle
and HIGH to the operating current principle.