Figure 26. fir filter stages, Table 14. fir filter characteristics, Teristics as described in figure 26 and table 14 – Cirrus Logic CS5378 User Manual

Page 46: Cs5378

Advertising
background image

CS5378

DS639F3

46

FIR1 – Single stage, fixed decimate by 4

Coefficient set 0: linear phase decimate by 4, 48 coefficients
Coefficient set 1: minimum phase decimate by 4, 48 coefficients

SINC droop compensation filter


FIR2 – Single stage, fixed decimate by 2

Coefficient set 0: linear phase decimate by 2, 126 coefficients
Coefficient set 1: minimum phase decimate by 2, 126 coefficients

Brick wall low-pass filter, flat to 40% f

s



Combined SINC + FIR digital filter specifications

Passband ripple less than +/- 0.01 dB below 40% f

s

Transition band -3 dB frequency at 42.89% f

s

Stopband attenuation greater than 130 dB above 50% f

s

Figure 26. FIR Filter Stages

SINC + FIR filters

FIR2
Output
Word
Rate

SINC
Deci-
mation

FIR1
Deci-
mation

FIR2
Deci-
mation

Total
Deci-
mation

Passband
Ripple

(

± dB)

Stopband
Atten-
uation
(dB)

4000 16

4

2 128

0.0042

130.38

2000 32

4

2 256

0.0045

130.38

1000 64

4

2 512

0.0040

130.42

500 128 4

2 1024

0.0041

130.42

333 192 4

2 1536

0.0080

130.45

250 256 4

2 2048

0.0064

130.43

200 320 4

2 2560

0.0043

130.44

125 512 4

2 4096

0.0046

130.42

100 640 4

2 5120

0.0040

130.43

50 1280 4

2 10240

0.0040

130.43

40 1600 4

2 12800

0.0040

130.44

25 2560 4

2 20480

0.0040

132.98

20 3200 4

2 25600

0.0036

130.43

10 6400 4

2 51200

0.0036

130.43

5 12800 4

2 102400

0.0036

130.43

1 64000 4

2 512000

0.0029

134.31

Table 14. FIR Filter Characteristics

Advertising