Operating Instructions

70400001

10

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Error Codes

Display

Definition

Corrective Action

OP

Open thermistor error

Check thermistor. Replace if inoperative.

Check wiring diagram between control and
thermistor. Refer to wiring diagram for proper
wiring.

Check control. Replace if inoperative.

SH

Shorted thermistor error

Check thermistor. Replace if inoperative.

Check wiring between control and thermistor.
Refer to wiring diagram for proper wiring.

Check control. Replace if inoperative.

AF - 1

Airflow switch closed when cycle
started

Check airflow switch. Replace if inoperative.

AF - 2

Airflow switch failed to close after
cycle started

Check airflow switch. Replace if inoperative.

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the tumbler is properly grounded.

W002