Alliance Laundry Systems 55 Pound Capacity User Manual

Page 20

Advertising
background image

Operating Instructions

70400001

18

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Programming

1. Set DIP switch #8 to the ON position.

2. Select the desired program number to change.

The LED should be flashing.

3. Select DRY TIME. Set the time with the Up/

Down arrows.

4. Select COOL TIME. Set the time with the Up/

Down arrows.

5. Select TEMPERATURE. Set the temperature

with the Up/Down arrows.

6. Press and hold the Program Select button about

3 seconds until the LED stops flashing. The
selected program number is now programmed. If
the Program button is pressed for less than
3 seconds, the controller will cancel the program
and display the next program’s settings. If not
programmed correctly, the display will flash
“E2F” for 4 seconds, and the default settings will
be used. Follow steps 4 through 7 to reprogram
any program number. When finished, set DIP
switch #8 to OFF. The programs are now stored.

7. During the Program Mode, if the Up/Down

arrows or Display button is not pressed within
10 seconds, the default program settings will be
used.

8. Temporary Reprogramming of Current Programs

(OPL ONLY)

9. The Drying Time, Cooling Time and

Temperature of a program currently in use may
be modified simply by adjusting any or all of the
program parameters for that program, as needed.
Once a modification has been made, the current
program LED will flash indicating that it has
been modified.

10. Use the Up/Down arrows to adjust program time.

11. Use the Display Select button to choose between

Drying Time, Cooling Time, and Temperature.
Then use the Up/Down arrows to adjust the times
and temperature.

12. To cancel this temporary programming mode

push the STOP button once to stop the current
cycle and once more to cancel the modified
program settings. The program will revert back to
its original settings.

Rotation Sensor

The rotation sensor must “read” the key on the basket
shaft or pulley. The sensor must be set approximately
1/4 inch from the key or pulley. Look for the light on
the sensor to come on as the key passes the sensor; this
is a correctly operating sensor. If no light appears,
either the sensor is out of range or the key/pulley or the
sensor is bad. In addition, if the light stays on
continuously, then the sensor is too close to the
component or the sensor is bad.

Safety Tumble/Anti-Wrinkle

At the end of the cool down cycle, the tumbler will
stop and display “END.” The DMP control will
automatically rotate the basket for 5 seconds every
2 minutes for a total of 20 minutes, until some
function of the tumbler is activated/deactivated by the
user.

Operational Check for the Board Diagnostics

1. “dor” indicates that the loading or lint door is

open.

2. Cycle the tumbler to check if the buzzer activates.

3. “P-F” indicates that the thermistor is short

circuited or open circuited.

4. “bbt” indicates a broken belt condition or a faulty

rotation sensor. (Only available on tumblers with
the rotation sensor.)

5. Hold the START button to display the drum

RPM’s; the display will read “r##” where ## are
the RPM’s. (Only available on tumblers with the
rotation sensor.)

Advertising
This manual is related to the following products: