Operating Instructions

70400001

12

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Door Open Mode

In Door Open Mode, the control turns off the heater
and motor when the door is opened during a run cycle.
The timer will continue to count down time and the IN
USE
LED is lit.

End of Cycle Mode

In End of Cycle Mode, a cycle is complete and the IN
USE
LED is off. The control remains in this mode
until the door is opened or additional vend has been
satisfied.

Topoffs

Any time the control receives a coin drop pulse during
a cycle it will add the programmed dry time to the time
currently remaining in the cycle. The maximum cycle
time is 99 minutes, the control will not add time
beyond 99 minutes. The cool down time will not
change.

If the control receives a coin drop pulse during cool
down the IN USE LED will flash briefly to indicate the
coin input, the machine will exit cool down and it will
start heating. The cycle time will be equal to the
programmed dry time

Temperature Selector Switch

For five minutes after the control is powered up, there
is a diagnostic feature that allows the temperature
selector switches to be tested.

When the temperature selector is changed, the new
setting is displayed by flashing the IN USE LED as
follows:

High/Normal: 4 flashes
Medium/PP: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash

NOTE: To change dipswitch settings refer to
Installation Manual
.

To Program a Short Test Cycle:

1. Unplug machine power cord.

2. Write down machine control dip switch settings,

then set them all to the off position. Refer to
Figure 5.

3. Plug machine in and start a cycle.

NOTE: With all control dip switches off, the total
cycle time will be 1 minute long.

4. Once all testing is complete, unplug machine and

re-set dip switches to their original settings.

5. Plug machine in.

Figure 5

Error Codes

TMB2216N

1 2 3 4 5 6 7 8

O
N

1

2345

6

78

Display

Definition

Corrective Action

AF (flashing)

Airflow switch opened/closed 5 or
more times in a running cycle.

Check airflow switch. Replace if inoperative.

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.