5. To Customize the Existing EIA Tone-to-Output Assignment:

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

ON

ON

8

7

6

5

4

3

2

1

Y

X

F5

F4

F3

F2

F1

PROG

A customized EIA Tone-to-Output Assignment is created by first loading a standard Pre-Set, then re-assigning as many outputs as desired to new
EIA Tone values. It is also possible to un-assign outputs from the loaded Pre-Set. Blank Pre-Sets are available for use in building a customized
EIA Tone-to-Output pattern “from scratch.”

a. Turn the Y switch ON.

b. Turn the PROG switch ON.

c. Use switches F1 through F5 to select a specific discrete output or binary pattern to be re-assigned or un-assigned.

d. The front panel LED's and the EIA Tone LED's indicate individual EIA Tone-to-Output assignments.

When the EIA Tone LED for the selected Output lights, use the Tone Select pushbutton to step through the EIA Tones. Press and
release the Tone Select pushbutton to advance the EIA Tone LED’s to the next Tone. Stop when the desired Tone is indicated.
(After the “450” EIA Tone is indicated, continued pressing of the Tone Select switch will continue with the “1950” Tone.)

A step is provided between EIA Tones “450” and “1950” in which no EIA LED’s are lit. Stopping at this step un-assigns the
selected Output from its EIA Tone. While an output is unassigned, it will not respond to any of the EIA frequencies.

The “Fx” pattern “00000” cannot be assigned an EIA Tone when using Discrete 1 of 5 or Discrete Split Pre-Sets.

When a Discrete Wildcard Pre-Set is used, a special condition exists for re-assigning the F5 “Wildcard” output. The “ON” EIA
Tone LED for F5 lights when switch F5 is ON and switches F1 through F4 are OFF. The “OFF” EIA Tone LED for F5 lights
when switches F1 through F5 are all OFF. To change the EIA Tone of either the ON or OFF function, press and release the Tone
Select pushbutton while the appropriate F1 through F5 switch arrangement is set up. Stop when the desired new EIA Tone is
reached. Output F5 cannot be unassigned when a Discrete Wildcard Pre-Set is used.

TP200 Product Description - 5/23/01 Page 15 of 28

e. After re-assigning or un-assigning an Output, either return to step c. to select another discrete output or binary pattern, or save

the newly the customized assignments by:

i. Turning the Y switch OFF.*

ii. Turning the PROG switch OFF.*

The TTP200 will then return to normal operation.

*Turning the PROG switch OFF before turning the Y switch OFF exits the Customize function without saving the new custom settings.

Example1: Re-Assign A Discrete One-of-Five Output from One EIA Tone to Another EIA Tone

After loading Pre-Set #2:

a. Turn the Y switch ON.

b. Turn the PROG switch ON.

c. Turn the F1 switch (S2-2) ON and switches F2 through F5 (S2-3 through S2-6) OFF.

d. With the 1950 EIA Tone LED lit, press and release the Tone Select pushbutton until the 1650 EIA Tone LED lights.

e. Turn the Y switch OFF.

f. Turn the PROG switch OFF.

g. The Discrete Output F1 will now be switched ON upon reception of the 1650 EIA Tone instead of the 1950 EIA Tone.