MULTITASKER™

400-0095-005

12

12

The output volume line shows the current output
volume level and the input level line lists the
gain setting for each input, 1-8. The maximum
input and output values are 32.

The mute line shows the output’s status, off or
on. A “0” indicates mute is off (output is
enabled) and a “1” indicates mute is on (output
is disabled).

6. [STA1]

This command enables automatic feedback
from the front panel. The command affects any
card with auto-feedback capability, not just the
MT109-100. The default at power up, or after a
reset is STA0, off. For more details, see the
[?Cn] command definition.

Command Format [STA1]: = On

Feedback Prefix Definitions:
MT

Card model number

VR

Firmware revision

IN

Input selection

VO

Output volume level

VI

Input gain settings

VM

Mute setting

Example:

Command =

[ON1C4]

Feedback =

(IN1C04)
IN

=

Input selection

1

=

Setting (1-8)
Input 1 active

C04 =

Card/Slot number

7. [STA0]

This command disables automatic feedback
from the card and front panel. The command
affects any card with auto-feedback capability,
not just the MT109-100 card.

The default at

power on or reset is STA0, OFF.

Command Format: [STA0]

8. [ +O ]

This command increases the output volume
level by 1 up to the maximum level of 32. If the
command is sent after a level of 32 has been
reached, it will have no effect on the output.

Command Format: [+OCnUi]

Cn = Card ID

Ui

= Unit ID (i = # from 0 to 9)

Example:

Increase the output volume of C4 (slot 4) from
31 to 32 by sending the command [+OC4].

9. [ -O ]

This command is the same as [+O] except that
it decreases the output volume level by 1 down
to the minimum level of 1.

10. [ +I ]

This command increases an input level by 1 up
to the maximum level of 32. If the command is
sent after a level of 32 has been reached, it will
have no effect on the input.

Command Format: [+ImCnUi]

m

= Input No. (m - # from 1 to 8)

Cn = Card ID

Ui

= Unit ID (i = # from 0 to 9)

Example:

Increase the output volume of C4 (slot 4) from
31 to 32 by sending the command [+OC4].

11. [ -I ]

This command is the same as [+Im] except that
it decreases an input level by 1 down to the
minimum level of 1.

12. [ + ] See the [SEL] command.

13. [ - ] See the [SEL] command.

14. [SEL] and [SELm]

These commands allow the input levels and
output volume to be adjusted incrementally.

OUTPUT Command Format: [SELCnUi]

Cn = Card Slot Number

Ui

= Unit ID (i = # from 0 to 9)