MS-91E2

1-5

Overvew

MS-91E2

D. Enable watchdog tmer

Actvate WDTO#

mov

dx, 04eh ;CR 30h: bit 0 fill in 1

mov

al, 030h

out

dx, al

nc

dx

mov

al, 01h

out

dx, al

; Setup WDTO# count mode

; Set bt 4 and bt 3 by request

; Set bt 2 to 0

; Set bt 1 to 1