Multitasker – Altinex MT113-101 User Manual

Page 16

Advertising
background image

MULTITASKER™

400-0209-002

15

15

Command Format: [RUP=xxCnUi]

xx = Stop Level (xx = # from 01-16)

Cn = Card ID (n = # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume from a starting level of
1 up to 10. Send the command [RUP=10C8]
and receive the following feedback:

[02][03][04]…[10]

25. [RDN]

This command ramps the OUTPUT volume
down to a level of 1 at a rate defined using the
[RAMP] command.

Command Format: [RDNCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume from a starting level of
16 down to 1 for the card in slot #8. Send the
command [RDNC8] and the system will respond
with the following feedback:

[16][15][14]…[01]

26. [RDN=]

This command ramps the OUTPUT volume
down to a user defined level at a rate defined
using the [RAMP] command.

Command Format: [RDN=xxCnUi]

xx = Stop Level (xx = # from 01-16)

Cn = Card ID (n = # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

Ramp the output volume from a starting level of
16 down to 8 for the card in slot #8. Send the
command [RDN=8C8] and the system will
respond with the following feedback:

[16][15][14]…[8]

27. [RST]

This command stops ramping and maintains the
last volume setting.

Command Format: [RSTCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

The card in slot #8 is ramping from 1 to 16.
Send the command [RSTC8] and the card will
stop ramping the volume. The last displayed
volume setting is the new volume level.

28. [RAMP]

This command displays the ramping time for 16
steps. The time between each step is equal to
the time in seconds divided by 16.

Command Format: [RAMPCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

Display the ramp rate setting for the card in slot
#8 by sending [RAMPC8]. The system will
respond with feedback similar to the following:

RAMPTIME = 6 SECONDS

29. [RAMP=]

This command sets the ramp rate for 16 steps.
The settings range from 4 to 18 seconds, in
two-second intervals.

Command Format: [RAMP=xCnUi]

x

= Rate in Seconds

4

= 0.25 seconds/step

6

= 0.38 seconds /step

8

= 0.50 seconds /step

10 = 0.63 seconds /step
12 = 0.75 seconds /step
14 = 0.88 seconds /step
16 = 1.00 seconds /step
18 = 1.13 seconds /step

Cn = Card ID (n = # from 1 to max slots)
Ui

= Unit ID (i = # from 0 to 9)