MCP400 Manual Call Point

• For use with Ei151TLR, Ei156TLR, Ei161R,

Ei164R or Ei166R alarms

• Supplied complete with surface

mount box

• Testing key supplied

• Supplied with non-breakable

operating element

• Suitable for use with Modifire

• LPC approved, conforms to

BS EN 54-11

Ei159 Smoke Alarm
Locator Switch

This convenient unit allows the user to

locate the precise source of an

alarm in installations comprising three

or more units. Pressing the locator

button stops all the alarms sounding

except for the one that was the

source of the alarm.

• The ideal way to quickly and easily

find the source of any alarm

• Easy to install

• Ideal for larger premises and HMOs

• Auto reset within ten minutes

• Minimises disturbance to other

residents

• Suitable for use with any of the

140, 150 and 160 series alarms

Ei128R Relay Base - mains
powered only

• For use with 140 and 160 series

• Surface Mount Kit or pattress

• 5 amp relay with volt free contacts

• Switchable for constant or pulse

operation

• Allows signalling to door closers,

sounders, strobes etc

• Suitable for use with Modifire

Ei128RBU Relay Base
- mains with rechargeable
back-up

• For use with 140 and 160 series

• 5 Amp relay with volt free contacts

• Switchable for constant or pulse

operation

• Features rechargeable lithium back-

up cells with 10 yr+ life

• Ideal for signalling to devices not

affected by a mains failure, such as

Warden Call Systems

MODIFIRE

A Modifire system is exceptionally simple

to design and install, thanks to its modular

design and unique Easi-fit technology.

Just tailor the system to meet the needs

of the premises. The Ei161R ionisation or

Ei166R optical alarm with rechargeable

back-up provides the starting point. Then

you can add extra alarms, call points and

locator switches as required, all

interconnected with PVC mains wiring

cable. Only one ‘R’ unit - Ei161R or Ei166R

- is necessary for each system.

BASIC SYSTEM (GUIDE ONLY)

• System to cover escape routes only

• Choose from Ei161R ionisation or Ei166R

optical alarms

• Connect Manual Call points MCP400

into the circuit

INTERMEDIATE SYSTEM
(GUIDE ONLY)

• System to cover escape routes AND

high risk areas

• Install Ei161R or Ei166R alarm and add

further ionisation (Ei161), optical (Ei166)

and heat alarms (Ei164) as required to

a maximum of 20 alarms. The Ei128R

relay base counts as one alarm

• Connect into the circuit Manual Call

Points MCP400 as required

• Connect into the circuit Alarm Locator

Switches Ei159 as required

• Mount an Ei128R or Ei128RBU relay base

behind the ‘R’ unit to signal warden call

devices, strobes, sounders etc

BASIC SYSTEM (GUIDE ONLY)

INTERMEDIATE SYSTEMS (GUIDE ONLY)