problem

possible cause

corrective action

Power On/Off switch is

turned on, but the switch

indicator Light is still off

and the unit is not heating

up.

the power cord is not correctly plugged

in.

Plug the power cord in correctly.

the power cord and/or electrical plug is

damaged.

inspect electrical wire, plug, and recep-

tacle.

the main electrical panel circuit breaker

is off, or has been tripped.

Reset circuit breaker. contact your main-

tenance person or authorized service

agency if it trips again.

switch is inoperable.

contact your maintenance person or

authorized service agency for service.

the unit’s main electrical

panel circuit breaker trips.

Damaged receptacle, plug, or cord; a

loose connection or an internal compo-

nent failure.

turn the unit off, allow it to cool to room

temperature, and then restart the unit.

contact your maintenance person or

authorized service agency if condition

repeats.

Power On/Off switch is

turned on, the switch indi-

cator light is on, but the

unit is not heating up.

Hi-Limit thermostat is tripped.

Reset the Hi-Limit according to the

Operation section of this manual. if it

requires continuous resetting or repair,

contact your maintenance person or

authorized service agency for service.

inoperable thermostat.
inoperable generator.
Loose/burnt wiring.

unit heats but there is lit-

tle or no steam produced

and/or

the product requires more

steaming than usual.

Water Line valve is closed.

check that the Water Line Valve is open.

filter strainer is restricted.

check and clean the filter strainer as

described in the Maintenance section of

this manual.

Quick Disconnect is not fully engaged at

rear of unit or is damaged.

Remove and re-engage the Quick

Disconnect insert firmly until a “click” is

heard. Replace if damaged.

Low or no water pressure in water line.

Remove the Quick Disconnect insert from

the rear of the unit. While holding over a

bucket, press the “white” plastic tip. strong

Water flow should be noted. if so, recon-

nect firmly into unit. if

spray tube is restricted.

Remove and clean the spray tube accord-

ing to the Daily Maintenance procedures

found in this manual.

black Manifold orifices are restricted.

Remove and clean the black Manifold

according to the Daily Maintenance proce-

dures found in this manual.

unit is not being cleaned daily and/or

properly.

clean unit Daily according to the Daily

maintenance procedures found in this

manual.

improper water pressure to unit.

Verify that a Water Pressure Regulator is

installed and set to 20-2 Psi.