Variety steamer, Troubleshooting (continued) – Antunes, AJ VS-200aSb User Manual

Page 17

Advertising
background image

17

Variety SteaMer

P/N 1010649 Rev. E 03/07

trOUblesHOOtInG (continued)

problem

possible cause

corrective action

unit heats but there is little

or no steam produced

and/or

the product requires more

steaming than usual.

(continued)

insufficient or excessive calcium/mineral

buildup on generator surface.

Verify that a thin layer of calcium/mineral

deposits is present on the generator sur-

face. Refer to the Maintenance section of

this manual.

black Manifold O-ring is worn, damaged,

or missing.

Replace the black Manifold O-ring if worn,

damaged, or missing.

Low generator temperature.

Verify generator surface temperature is at

least 380° f (193° c),

steam leaks out of the

sides of the unit.

black Manifold O-ring is damaged or

missing.

Replace the black Manifold O-ring if worn,

damaged, or missing.

black Manifold is difficult

to remove or re-install

onto the generator.

black Manifold not being removed and

cleaned daily as required.

Remove and clean the black Manifold

Daily according to the Maintenance section

of this manual.

black Manifold O-ring is damaged or

worn.

Replace the black Manifold O-ring if dam-

aged or worn.

black Manifold O-ring is not being lubri-

cated daily with Petro gel.

Lubricate the black Manifold O-ring daily

according to the Maintenance section of

this manual.

unit floods over night

and/or continues to steam

even when just in ready

mode.

solenoid valve is being held open by

debris from the building’s water line pip-

ing.

attempt to flush the debris out of the valve

by operating the unit on a number of cycles

and then letting it rest. if the unit still

leaks, contact your maintenance person or

authorized service agency.

there is no pre-strainer/filter on the water

line just before the unit.

Advertising