Controlling and monitoring – Axis Communications 250S User Manual

Page 49

Advertising
background image

AXIS 250S User’s Manual

Unit Connections

49

Controlling and Monitoring

By entering http requests in your browser’s URL field, you can:

• drive the transistor output high or low
• monitor the status of the 4 digital inputs
This requires you to have root access to the AXIS 250S and consequently, to supply a user

name and password. Login as root and supply the root password (default = pass).

Tip!

Transistor Output

You can use the supported output to directly drive a maximum load of 24V DC at 100mA.

By connecting additional relay circuitry, it can also drive heavier loads.

The transistor output is controlled using http requests, as shown in the following examples:

Example 1: -

Set output 1 ON

Example 2: -

Set two 300ms pulses with 500ms delay between the pulses on output 1.

Example 3: -

Wait 1 second before setting output 1 ON.

Digital Inputs

Four digital

inputs allow the AXIS 250S to be configured for device triggered events. For

example, by connecting a motion detector to a digital input, it is a relatively simple

procedure to trigger an event each time the detector is activated.

Querying the Status of Digital Inputs

The status of the four supported digital inputs can be queried in exactly the same way as

the relay output. Simply enter the following URL to query the status of the digital inputs:

Example: -

Monitor data on input ports 1, 2, 3, and 4

Developers wishing to create applications incorporating sophisticated alarm conditioning using the
transistor output and digital inputs are encouraged to read the Camera API, HTTP-Interface Specifica-
tion, available from the Axis Web at www.axis.com.

http://myserver/axis-cgi/io/output.cgi?action=1:/

http://myserver/axis-cgi/io/output.cgi?action=1:/300\500/300\

http://myserver/axis-cgi/io/output.cgi?action=1:1000/

http://myserver/axis-cgi/io/input.cgi?check=1,2,3,4