Problems - causes - solutions – Ariston MCA 15 NA P User Manual

Page 24

Advertising
background image

24

NA

Problem Cause

Solution

The machine does not switch on

The machine is not connected to the
power supply

Check connection to the power
supply

Coffee is not hot enough

The cups are cold

Warm the cups with hot water

No hot water or steam is dispensed

Steam spout clogged

Pull the steam spout downwards to
remove it, and clean

Coffee brews too slowly

Coffee too fine

Change coffee blend

Rotate the grind regulation knob to
the highest number

Brew group dirty

Wash the brew group

SBS system knob turned all the way
to the right

Turn the knob to the left and when
the machine is brewing, turn toward
the right

Coffee brews too quickly

Coffee too coarse

Change coffee blend

Rotate the grind regulation knob to
a lower value

SBS system knob turned all the way
to the left

When the machine is brewing, turn
the knob to the right

The machine takes a long time to
heat up and the amount of water
dispensed from the spout is too
small

There are limescale deposits in the
circuit

Run descaling cycle

The brew group does not come out

The brew group is off position

Turn the machine on. Close the
front door; the group returns to
the starting position and can be
removed.

Drip tray inserted

Remove the drip tray

Coffee leaks out of the brew unit

Brew unit in the wrong position

Reposition the brew unit

Brew unit clogged

Remove brew unit and wash

Coffee has little foam

Unsuitable coffee blend or coffee is
not freshly toasted

Change coffee blend

Coffee blend too coarse

Regulate the grind

SBS system knob turned towards
the left

Turn the SBS system knob to the
right

Water overflowing from the drip tray Drip tray too full

Check the position of the float and
empty the drip tray

Problems - causes - solutions

CUSTOMER CARE, SERVICE OF PARTS: 1-877-356-0766 or e-mail to: [email protected]