Ariston MCA 15 NA P User Manual

Page 5

Advertising
background image

NA

5

Water connection

! Before connecting the supply pipe to the water
mains, let the water flow until it is clear.

! The distance between the sources for the electric
and the water connections have to comply with the
regulations in force at the moment of installation.

1. Remove the
protective cap from the
water outlet.

! All protective parts must be attached so that they
cannot be removed without the aid of a tool.

Next replace the protection and the drip tray.

Electrical connection

! Coffee machines with three-pole power cable are
regulated for alternating current, with voltage and
frequency shown on the rating plate attached to the
appliance.

! The installer is responsible for checking the correct
connection of components and observing safety
regulations.

Before connecting make sure that:
• the socket is earthed and is compliant with statutory

regulations:

• the socket is able to withstand the maximum power

load of the machine, shown on the rating plate;

• the supply voltage is within the values shown on the

rating plate;

• the socket is compatible with the appliance’s plug.

Otherwise replace the plug or the socket; do not use
extension leads or adaptors.

! Once the appliance is installed, the electric cable and
socket must be easy to reach.

! The power cable must not be subject to coiling or
compression.

! The cable must be checked regularly and replaced
only by authorised technicians.

! The company accepts no responsibility for non-
compliance with these regulations.

Installing the power cable

• Put the plug in the
tray socket on the rear
of the machine

• Connect the power
cable to the mains

• Put the plug in the
power socket.

The position of the
power cable must be

such that no section of it is above room temperature
by more than 50°C/122°F.

2. Connect the supply
pipe to the machine
by inserting it in the
appropriate water
outlet, in the rear side
up on the right (see
figure).

3. Fasten the supply
pipe to a cold water tap
with a threaded 3/4 gas-
type connection (see
figure).

4. Make sure that there are neither bends nor

constrictions in the pipe.

! The water pressure of the tap has to be within the
values shown in the Technical Specification table.

! If the length of the supply pipe is not enough, please
refer to a specialised point of sale or an authorized
technician.

! Never employ used or old inlet pipes, but only those
provided with the machine.

Advertising