Bryant T6-NHP User Manual

Page 48

Advertising
background image

46

temperature sensed by the working sensor every 10 seconds. The control will

operate from the temperature sensed by the working sensor.
E1 − If the Display Module and the Equipment Control Module cannot

communicate via two−wire connection, an E1 will be displayed.
E2 − There is no E2 error message.
E3 − If AC/HP Control cannot properly read outdoor temperature, and it is

needed for proper operation, display will indicate “−−” in the outdoor

temperature location.
E4 − If AC/HP Control’s internal memory fails, E4 will be displayed. Replace

AC/HP Control.
Table 3 can be used as a troubleshooting tool for determining which outputs will

be active for a particular configuration and each operating mode.
When replacing a failed component such as an equipment control module or a

display module, the installer should replace both parts as a matched set. It is very

easy to accidentally mix an A/C or HP display with a PAC equipment control

module. When this happens, some functions appear in the setup while others do

not. This can be very confusing to troubleshoot. Verify that both parts have the

same model and serial number when troubleshooting the thermostat.