7 programming – BEA 10MATRIX User Manual

Page 3

Advertising
background image

75.1046.04 EN 20080505

Page 3 of 5

7 Programming

I. THE 3 CONFIGURATIONS

A. Configuration A: Single Loop Detector (MATRIX-S)

B. Configuration B: Dual Loop Detector in Independent Mode with Dipswitch #10 OFF (MATRIX-D)

C. Configuration C: Dual Loop Detector in Combined Mode with Dipswitch #10 ON (MATRIX-D)

II. POTENTIOMETERS

A Potentiometer for Adjustment of the Maximum Duration of a

Presence Detection: from 1 min to Infinity (See PRESENCE TIME)

A Potentiometer for Adjustment of the Linear Sensitivity ( f)

for the Loop A: from 0.005% to 0.5% (See SENSITIVITY)

A Potentiometer for Adjustment of the Linear Sensitivity ( f)

for the Loop B: from 0.005% to 0.5% (See SENSITIVITY)

III. RELAY CONFIGURATION (DIPSWITCH #3)

A 10 position dip switch is located on the front of the Matrix single detector. Dip switch 3, 5, 6, 7 and 8 configure the relay, while dip switch 9

controls the duration of the pulse when the Matrix is configured for pulse operation, (as opposed to presence). Configurations are as follows:


DIPSWITCH 3:

OFF= FAIL-SECURE MODE Relay is NOT energized when power is applied. Relay is energized upon detection only. In this mode, the NO

circuit is open, and the NC circuit is closed. Thus, if a closed circuit is required upon detection, one must use the NO and COM terminals

since they would close upon detection. When the Matrix is NOT powered, it is in the same state as it would be for non-detection.

ON = FAIL-SAFE MODE Relay is energized as soon as power is applied and de-energizes upon detection or power loss. In this mode, upon

powering the detector, the NO circuit becomes closed, and the NC circuit becomes open. Thus, if a closed circuit is required upon detection,
one must use the NC and COM terminals, since they would now be OPEN during non-detection, and would close upon detection. When the

Matrix is NOT powered, it is in the same state as it would be for detection.

Configuration A

Single loop

Configuration B

Dual loop in independent mode

Configuration C

Dual loop in combined mode

Dip Switch

OFF

ON

OFF

ON

OFF

ON

DS#1

High (loop A)

Low (loop A)

[High –30%]

High (loop A)

Low (loop A)

[High –30%]

DS#2

See next table

High (loop B)

Low (loop B)

[High –30%]

High (loop B)

Low (loop B)

[High –30%]

DS#3

Active mode

Passive mode

Active mode

Passive mode

Active mode

Passive mode

DS#4

ASB OFF

ASB ON

ASB OFF

ASB ON

ASB OFF

ASB ON

DS#5

Relay A :

Presence on

loop A

Relay A :

Pulse on loop

Relay A :

Presence on loop A

Relay A :

Pulse on loop A

Not used

Not used

DS#6

Relay A :

Pulse on loop

A

entry

Relay A :

Pulse on loop A

exit

Relay A :

Pulse on loop A

entry

Relay A :

Pulse on loop A

Exit

Relay B :

Non-Directional

mode

Relay B:

Directional AB

mode

DS#7

Relay B :

Presence on

loop A

Relay B :

Pulse on loop A

Relay B :

Presence on loop B

Relay B :

Pulse on loop B

Relay B :

Pulse on loop B

Relay B :

Pulse on loop A

DS#8

Relay B :

Pulse on loop

A

entry

Relay B :

Pulse on loop A

exit

Relay B :

Pulse on loop B

entry

Relay B :

Pulse on loop B

exit

Relay B :

Pulse on loop entry

Relay B :

Pulse on loop exit

DS#9

100 ms

500 ms

100 ms

500 ms

100 ms

500 ms

DS#10

Not used

Not used

Independent

Combined mode

Independent

Combined mode

Δ

Δ

MAX

1 min 10 min

1 hr

2

5

20

Infinity

PRESENCE TIME

hr

hr

hr

MIN

0.5% 0.44%

0.34%

0.25%

0.18%

0.1%

0.005%

SENSITIVITY

MAX

MIN

DETECTION STATUS

FAIL-SECURE MODE (Active Mode)

(Relay is not energized upon power-on)

DIPSWITCH 3 = OFF

FAIL-SAFE MODE (Passive Mode)

(Relay becomes energized upon power-on)

DIPSWITCH 3 = ON

NO DETECTION

The COM and NO terminals are OPEN.

COM and NC terminals are CLOSED.

The relay is de-energized.

The COM and NO terminals are CLOSED.

COM and NC terminals are OPEN.

The relay is energized.

DETECTION

The COM and NO terminals are CLOSED.

COM and NC terminals are OPEN.

The relay is energized.

The COM and NO terminals are OPEN.

COM and NC terminals are CLOSED.

The relay is de-energized.

UPON POWER LOSS

The COM and NO terminals are OPEN.

COM and NC terminals are CLOSED

The relay is de-energized.

The COM and NO terminals are OPEN.

COM and NC terminals are CLOSED.

The relay is de-energized.

Same

Same