8 Adjustments

7 Programming (cont’d)

IV. DIPSWITCHES

A. After each dipswitch change the sensor launches a learning process.

DIPSWITCH

LEARNING PROCESS

#1

Frequency Adjustments of Loop A (see ADJUSTMENTS)

#2

Frequency Adjustments of Loop A (with single loop) or Loop B (with Dual Loops)

#3

Relay configuration: Active (Fail-Secure) or Passive (Fail-Safe)(See Programming Step III.)

#4

Automatic Sensitivity Boost (ASB option) [recommended for improved truck detection] :
During a detection, the sensitivity increases automatically to 8 times the preset sensitivity given by the sensitivity

potentiometer adjustment. It is limited to the maximum sensitivity ( f = 0.005%). It goes back to the preset value after

detection stops.

#5

Relay A Function: Presence or Pulse (not used with dual loop in combined mode)

#6

Relay A Pulse type: Entry or Exit (used only at pulse function)

or Relay B Mode (with dual loop in combined mode) (see drawing on next page)

• Non-Directional: Relay B provides a pulse according to the dip switches #7 and #8 setting.

• Directional A B: Relay B provides a pulse only if loop A is detecting before loop B. The logic detection takes place

according to dip switches #7 and #8.

WARNING: DURING THE DETECTION, THE 2 LOOPS HAVE TO DETECT SIMULTANEOUSLY FOR A SHORT

PERIOD TO BE ABLE TO DETERMINE THE MOVEMENT DIRECTION. DURING LOOP INSTALLATION
MAKE SURE THE 2 LOOPS ARE CLOSE ENOUGH TO EACH OTHER TO ENSURE A COMMON
DETECTION (TYPICAL 3 FEET).

#7

Relay B Function: Presence or Pulse - or -
Loop Selection for Relay B Pulse: Pulse on Loop B or Pulse on Loop A (used with dual loop in combined mode)

#8

Relay B Pulse Type: Entry or Exit (used only at pulse function)

#9

Pulse Duration for Both Relays (used only at pulse function): 100 ms or 500 ms

#10

Dual Loop Mode: Independent or Combined A B (not used with single loop)

Δ

entry B

Pulse on exit A

Pulse on exit B

Dual Loop Configuration A

Relay B

(Directional A-> B mode)

Pulse on entry A

Pulse on entry

Relay B

(Non-Directional)

Loop A

Loop B

Relay A

Pulse on entry A

Pulse on

B

Pulse on exit A

Pulse on exit B

Loop A

Loop B

Dual Loop Configuration B

Loop A

Loop B

Relay A

Pulse on entry B

Pulse on exit B

Pulse on entry A

Pulse on exit A

Relay B

(Non-Directional)

Pulse on entry B

Pulse on exit B

Pulse on entry A

Pulse on exit A

Relay B

(Directional A-> B mode)

Loop A Loop B

FREQUECY ADJUSTMENT FOR LOOP A FOR SINGLE LOOP DETECTOR

LOOP FREQUENCY

DIPSWITCH #1

DIPSWITCH #2

HIGH

Off

Off

MID HIGH (High - 20%)

On

Off

MID LOW (High - 25%)

Off

On

LOW (High - 30%)

On

On