Installation – Broan ERV90HCS User Manual

Page 14

Advertising
background image

3.8.2

A

SSEMBLING

D

UAL

E

XTERIOR

H

OOD

*

Exterior dual hood is coming in separate parts. Using 2 no. 8 x 3/4” screws, assemble the top
metal screen and the plastic grille to the dual exterior hood. Then, slide the bottom metal
screen to the dual exterior hood. See illustration beside.

*P

ATENTED

.

3.8.3

L

OCATING THE

D

UAL

E

XTERIOR

H

OOD

The dual exterior hood must be installed at a minimum distance of 18 inches (457 mm) from the
ground. See illustration beside.

3.8.4

C

ONNECTING

T

ANDEM

T

RANSITION TO THE

D

UAL EXTERIOR

H

OOD

1. Using a jig saw, cut a 6” diameter hole in the exterior wall and insert the Tandem transition

through this hole.

3.8 I

NSTALLING THE

T

ANDEM

T

RANSITION

K

IT

(

CONT

D

)

3.8.1

C

ONNECTION TO

T

ANDEM

T

RANSITION

1. For each duct, pull back the insulation to expose the interior flexible duct.

2. Connect the interior flexible duct to the smaller part of the Tandem Transition (5” oval) using a tie wrap.

3. Pull the insulation over the joint. Pull the vapor barrier over the insulation.

4. Apply duct tape gently to the joint in order to make an airtight seal. See figures below.

3. INSTALLATION

(CONT’D)

VJ0025

VJ0022

VJ0023

VJ0024

1

2

3

4

E

XHAUST AIR TO OUTSIDE

DUCT ON TOP

VO0024

WARNING

Make sure this hood is at least 6 feet (1.8 m) away (or more, as per applicable building
codes or standards) from sources of contamination such as:

• High efficiency furnace vent
• Any exhaust from a combustion source
• Gas meter exhaust, gas barbecue-grill
• Garbage bin

!

VD0083A

18”

(457 mm)

VD0084

1

CAUTION

The Tandem Transition must be inserted in such a way that the

Exhaust air to outside duct will be located on the top.

- 14 -

1) E

XHAUST AIR TO OUTSIDE DUCT

Advertising
This manual is related to the following products: