Controls, Electrical connection to the furnace, Cont’d) 4.4 o – Broan ERV90HCS User Manual

Page 19: 2 60-m

Advertising
background image

4. CONTROLS

(CONT’D)

4.4

O

PTIONAL

A

UXILIARY

W

ALL

C

ONTROLS

O

PERATION

4.4.1

20-M

INUTE

L

IGHTED

P

USH

-B

UTTON

T

IMER

Set the push-button timer to ON. The fan motors will then operate at high speed for 20 minutes and the
indicator will light up.

To stop activation, push one time; the unit will then get back to previous selection.

4.4.2

60-M

INUTE

C

RANK

T

IMER

This control makes the system operate at high speed for periods varying from 10 to 60 minutes.

VC0084

ON

OFF

10

20

30

40

50

60

TURN

PAST

20

VC0017

4.4.3

H

UMIDITY

C

ONTROL

Setting during the fall, winter and spring months:
Adjust knob to the desired maximum humidity level.

Setting during summer:
Adjust knob to the OFF positon.

CAUTION

Do not select a humidity level below 30%. This could lead to excessive dryness in
the air causing discomfort for the occupants.

COM

FOR T

ZON

E

O

FF

%

REL

ATIVE HUMIDIT

Y

70%

60%

50%

40%

30%

25%

20%

HUMIDITY
CONTROL

VC0085

5. ELECTRICAL CONNECTION TO THE FURNACE

For a furnace connected to a cooling system:

On some older thermostats, energizing the “R” and “G” terminals at the furnace has the effect of energizing “Y” at the thermostat and
thereby turning on the cooling system. If you identify this type of thermostat, you must use the alternate furnace interlock wiring.

Standard furnace interlock wiring

Alternate furnace interlock wiring

WARNING

Never connect a 120-volt AC circuit to the terminals of the furnace interlock (standard wiring). Only use the low
voltage class 2 circuit of the furnace blower control.

0

!

W

R

G

Y

W

R

G

C

Y

UNIT TERMINAL

CONNECT

OR

THERMOSTAT

TERMINALS

FOUR
WIRES

TWO WIRES

heating only

FURNACE

24-VOLT

TERMINAL BLOCK

TWO WIRES

COOLING SYSTEM

N

O

C

N

C

I O

C

OL

Y

R G B

W R G

Y

W

R

Y

R

G

Y

C

THERMOSTAT

TERMINAL

4 WIRES

2 WIRES

heating only

wiring
nuts

FURNACE

24-VOLT

TERMINAL BLOCK

2 WIRES

COOLING SYSTEM

NO

NC

C

UNIT TERMINAL

CONNECT

OR

N

O

C

N

C

I OC

O

L

Y

R G B

VE0108A

- 19 -