Water Leakage Test

The final test after loading the camera is explained below. Always perform
this test. It can be performed easily in a water tank or a bathtub. Confirm
the operation of the different buttons. The required time is about
5 minutes.
• At first, immerse the Case for only 3 seconds and check that no water

enters the Case.

• Next, immerse the Case for 30 seconds and check that no water drop

etc. to the Case.

• Then, immerse the Case for 3 minutes, operate all buttons and levers,

and check the following:
- check that no water has entered the Case.
- check that the Case is not clouded.
- check that no water has entered the Case.

• If inside of the Case becomes cloudy or there is a water drop, do the

maintenance of the O-ring and perform the water leakage test again.

PT-056_EN.book Page 22 Thursday, February 13, 2014 11:12 AM