Using Acoustic Calibration EQ Professional

1

Select ‘EQ Professional’, then press ENTER.

2

Select an option and press ENTER.

Reverb Measurement – Use this to measure the
reverb characteristics before and after calibration.

Reverb View – You can check the reverb
measurements made for specified frequency ranges

in each channel.

1

Advanced EQ Setup – Use this to select the time
period that will be used for frequency adjustment and
calibration, based on the reverb measurement of
your listening area. Note that customizing system
calibration using this setup will alter the settings you
made in Automatically setting up for surround sound
(Auto MCACC)
on page 34 or Automatic MCACC
(Expert)
on page 68 and is not necessary if you’re
satisfied with these settings.

3

If you selected ‘Reverb Measurement’, select EQ

ON or OFF, and then START.
The following options determine how the reverb
characteristics of your listening area are displayed in
Reverb View:

EQ OFF – You will see the reverb characteristics of
your listening area without the equalization
performed by this receiver (before calibration).

EQ ON – You will see the reverb characteristics of
your listening area with the equalization performed
by this receiver (after calibration).

2

Note that the EQ

response may not appear entirely flat due to
adjustments necessary for your listening area.

3

When the reverb measurement is finished, you can select
Reverb View to see the results on-screen. See
Professional Calibration EQ graphical output on page 88
for troubleshooting information.

4

If you selected ‘Reverb View’, you can check the

reverb characteristics for each channel. Press RETURN
when you’re done.
The reverb characteristics are displayed when the

Full

Auto MCACC or Reverb Measurement measurements
are conducted.

4

Use

/ to select the channel, frequency and

calibration setting you want to check. Use

/ to go

back and forth between the three. The reverb
characteristics graph before and after EQ calibration can
be displayed by selecting

Calibration : Before / After.

Note that the markers on the vertical axis indicate
decibels in 2 dB steps.

5

If ‘Advanced EQ Setup’ is selected, select the

MCACC memory to be stored, then enter the desired

time setting for calibration, and then select START.

5

Based on the reverb measurement above, you can
choose the time period that will be used for the final
frequency adjustment and calibration. Even though you
can make this setting without reverb measurement, it is
best to use the measurement results as a reference for
your time setting. For an optimal system calibration
based on the direct sound coming from the speakers, we
recommend using the

30-50ms setting.

Use

/ to select the setting. Use / to switch

between them.

Select the setting from the following time periods (in
milliseconds):

0-20ms, 10-30ms, 20-40ms, 30-50ms, 40-

60ms, 50-70ms and 60-80ms. This setting will be applied
to all channels during calibration.

When you’re finished, select

START. It will take about 2

to 4 minutes for the calibration to finish.

After the Acoustic Calibration Equalization is set, you are
given the option to check the settings on-screen.

Note

1 If the

Reverb View procedure is performed after the Automatically setting up for surround sound (Auto MCACC) on page 34 or Reverb

Measurement operation, depending on the standing wave control setting, differences may appear on the reverb graph. With the Auto MCACC
function, the reverberations are measured with the standing waves controlled, so the reverb characteristics graph shows the characteristics
with the effect of the standing waves eliminated. By contrast, the

Reverb Measurement function measures the reverberations without

controlling the standing waves, so the graph indicates the reverb characteristics including the effect of the standing waves. If you wish to
check the reverb characteristics of the room itself (with the standing waves as such), we recommend using the

Reverb Measurement

function.

2 • The calibration corresponding to the currently selected MCACC preset will be used when

EQ ON is selected. To use another MCACC preset,

press

MCACC to select the MCACC memory you want to store.

• The predicted reverb characteristics after calibration can be acquired with the

Full Auto MCACC function (Automatically setting up for

surround sound (Auto MCACC) on page 34), but here the actually measured reverb characteristics after calibration can be acquired.

3 After auto calibration with

EQ Type : SYMMETRY (Full Auto MCACC, etc.), the graph for the inferred reverb characteristics can be displayed

by selecting

Reverb View. To display the actually measured reverb characteristics after EQ calibration, measure with EQ ON.

4 The

After display when measurements have been made using the Full Auto MCACC or Auto MCACC (ALL or KEEP SP system) function

shows the graph for the inferred reverb characteristics after

EQ Type : SYMMETRY calibration.

5 To specify the place where the MCACC memory is to be stored, press

MCACC to select the MCACC memory you want to store.