Hale MiniCAFS 2.1A (MC50 with FoamLogix System) User Manual

Page 17

Advertising
background image

17

MiniCAFS 2.1A Operating Manual
GP/211/05 Issue 2. April 2005

©Hale Products Europe. Our policy is one of continuous development. We therefore
reserve the right to amend specifications without notice or obligation.

FoamLogix Control Panel

1. Discharging foam agent only

1.1. Set water feed from supply pump at required pressure
1.2.

Ensure that the foam only option is selected by pressing the bottom of the
Foam/CAFS selector switch, marked with the symbol -

(No.3, Page 7)

1.3. Press the red on button, and choose desired foam % setting. (Default is 0.5%)

Foam %
Press ↑ to increase foam %
Press ↓ to decrease foam %

1.4. Open CAFS discharge valve to deliver foam agent.


Note: the WET/DRY control (ARC valve) is only operable when CAFS is selected. The
control will default to the wet condition when CAFS is turned off.


2. Discharging CAFS

2.1. Select CAFS by pressing the top of the CAFS selector switch – marked “CAFS”

(No.3 Page 7)

2.2. Ensure that engine throttle on MiniCAFS is fully open
2.3. Open CAFS discharge valve to deliver foam agent.

Advertising