FAULT FINDING

EFFECT CAUSE

ACTION

Compressor overheats

No water supply or restricted flow

Turn on water supply.
Check oil cooler pipe work
for obstructions

Unable to produce foam
solution

FoamLogix not operating

Switch on engine ignition
Switch on FoamLogix

No Foam in tank

Refill with foam agent

No air injection

CAFS switch not on

Turn CAFS switch on

Low foam switch activated
(If fitted)

Refill foam Tank

Air and liquid not mixing
(Slugflow)

Depleted foam supply (Low level
switch not fitted)
Foam % set too low

Refill foam tank

Increase foam % setting

Surging of hose and
pressure gauge.

Insufficient air pressure in hose

Increase compressor speed
if not at maximum.