TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

Sluggish Heater

Obstruction in chimney

Check for and remove
obstruction

Wet or unseasoned wood
being burned.

Burn dried natural seasoned
hard wood.

Poor chimney draft

Improper chimney height or
wrong size flue is being used.
Cooler temperatures caused
by external chimney.

High Fuel Consumption

Improper regulation of draft
or inlet air

(a) Close inlet air control as

much as possible to
maintain desired heat
output.

(b) Check gaskets, reinstall

fiberglass gasket around
doors and glass as
necessary

Improper door fitting

Check door gasket, check
adjustment of door latch.

Backpuffing Gusts

of

Wind

Chimney may need wind
diverts. Raise chimney for
better draft.

Smoke rolls out when heater
door is opened.

Wind gusts blowing down the
chimney

Chimney may need wind
diverts. Raise chimney for
better draft.

Opening heater door too fast

Crack door for 15 seconds
before fully opening door.