Check Safety Valve

1.

Pull ring on safety valve (see Figure 6) and observe that
safety valve operates freely.

2.

If valve is stuck or does not operate smoothly, it must be
replaced with same type of valve.Take unit to authorized
service facility for repair.

Check Quick Connect Fittings and

Tank Drain Valves

1.

Push ON - OFF switch to OFF and unplug unit.

2.

Disconnect air tool or accessory from unit.

3.

Pull ring on safety valve to reduce air pressure. Release
safety valve ring.

4.

Open both drain valves (turn fully counterclockwise, see
Figure 3, earlier) and permit accumulated water to be
discharged.Valves should operate smoothly and have full
range of operation.

5.

After water has drained, close drain valves fully
clockwise.

NOTE: If drain valves are plugged, pull safety valve ring to
fully drain air from tank. Remove, clean and reinstall drain
valve.

Check / Change Pump Oil

Checking Oil Level

Use these steps to check oil level:

1.

Push ON - OFF switch to OFF and unplug unit.

2.

Place unit on a flat, level surface.

3.

Remove oil dipstick and wipe dipstick with clean cloth.

4.

Reinstall dipstick into oil fill opening.

5.

Carefully remove dipstick and verify that oil level is at
proper level (see Figure 7).

6.

If oil level is too low, add recommended oil to proper
level (see Figure 7). If oil is above MAXIMUM oil level,
remove excess oil, as described in next section.

7.

Reinstall oil dipstick.

Changing Oil

At recommended oil change interval, follow these steps:

1.

Push ON - OFF switch to OFF and unplug unit.

2.

Place unit on a flat, level surface.

3.

Remove oil dipstick and wipe dipstick with clean cloth.

4.

Position a suitable container under oil drain plug to
collect drain oil.

5.

Use an adjustable wrench to remove hex head drain plug.

MAINTENANCE

12

Figure 7 - Oil Fill Information

Drain Plug

Oil Fill

Location

MAXIMUM

Oil Level

PROPER

Oil Level

Inset of

Dipstick

Figure 6 - Safety Valve

Pressure Switch

• DO NOT touch compressor or tubing.
• Allow compressor to cool before servicing.

Operating air compressor and tubing are HOT
and can cause burns.

WARNING

• DO NOT direct air stream at self or others.

• Always wear ANSI Z87.1 approved safety glasses with side

shields.

Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.

WARNING

Safety Valve Ring