Storage, Check pump intake and exhaust valves, Check safety labels – Briggs & Stratton 074001 User Manual

Page 14: Overload protection reset, Warning

Advertising
background image

MAINTENANCE / STORAGE

14

5.

Replace air filter media in compressor filter housing.

6.

Position air filter cover over air filter media. Use phillips
screwdriver to secure cover with screw.

NOTE: Replace air filter media if it is extremely dirty.

Check Pump Intake and Exhaust

Valves

Once each year, certain internal compressor components
must be inspected. Have a trained service technician perform
this check, to include the air compressor pump intake and
exhaust valves.

Check Safety Labels

As often as desired or at least yearly, inspect all labels applied
to the air compressor. All safety labels should be present and
readable. Should any safety label be missing or illegible, obtain
a replacement from an authorized service center or call the
air compressor helpline at 1-800-743-4115.

Overload Protection Reset

This compressor is equipped with an overload protection
feature that protects the motor if it overheats. If the
compressor motor overheats and ‘trips’ this circuit breaker,
wait 15 minutes for the motor to cool.Then push the RESET
button located on the motor shroud (see Figure 10).

Also see the Troubleshooting section on page 15 for more
information.

STORAGE

Before you store your air compressor, make sure you
perform the following:

1.

Review “Maintenance” beginning on page 11 and perform
scheduled maintenance as necessary.

2.

Push ON - OFF switch to OFF and unplug unit.

3.

Turn pressure control knob counterclockwise until knob
turns freely.

4.

Remove air tool or accessory.

5.

Pull ring on safety valve and drain air from air tank to
reduce air pressure. Release safety valve ring.

6.

Drain remaining air and water from tank by opening
drain valves fully counterclockwise.

7.

Rock unit forward and back to agitate condensate as it
drains to obtain a more thorough emptying action.

8.

After water has been drained, close drain valves fully
clockwise.

9.

Protect electrical cord and air hose from damage (such
as being stepped on or driven over).

10. Store air compressor in clean, dry, indoor location.

Figure 10 - Overload Protection RESET Button

RESET Button

• DO NOT direct air stream at self or others.

• Always wear ANSI Z87.1 approved safety glasses with side

shields.

Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.

WARNING

Advertising