5 message valid 1 register, 5 registers for time triggered communication, Message valid 1 register – Bosch TTCAN User Manual

Page 29: Registers for time triggered communication

Advertising
background image

User’s Manual

BOSCH

- 29/77 -

Revision 1.6

TTCAN

11.11.02

manual_about.fm

3.4.5 Message Valid 1 Register

MsgVal32-1Message Valid Bits (of all Message Objects)

one

This Message Object is configured and should be considered by the Mes-
sage Handler.

zero

This Message Object is ignored by the Message Handler.

These registers hold the MsgVal bits of the 32 Message Objects. By reading out the MsgVal
bits, the CPU can check which Message Object is valid. The MsgVal bit of a specific Message
Object can be set/reset by the CPU via the IFx Message Interface Registers.

3.5 Registers for Time Triggered Communication

3.5.1 Trigger Memory Access Register (addresses 0x0F & 0x0E)

Rd/Wr

Read / Write
one

Write to selected Trigger.

zero

Read from selected Trigger.

Trigger Number

0x00-0x1F

The trigger is selected for data transfer between Trigger Memory
and IF1 Message Data B1 and B2 Registers.

Note :

The CPU may access the Trigger Memory only during Configuration Mode. During active mode,
the write to the Trigger Memory Access register is locked. The Trigger Memory access is
started by a write to the low byte of the Trigger Memory Access register.

3.5.2 IF1 Data B1 and B2 Registers for Trigger Memory Access

The trigger data of the TTCAN system matrix is stored in the Trigger Memory. The Trigger
Memory is accessed via the IF1 Data B1 and B2 Registers. The data transfer is controlled by
the Trigger Memory Access Register. The bits of IF1 Data B1 and B2 Registers correspond
with the bits of a Trigger Memory word according to the following table :

Note :

Accesses to the Trigger Memory are controlled by the Trigger Memory Access Register, which
selects a word of the Trigger Memory and specifies the direction of the data transfer.

On each transfer, 32 bits are loaded either from the IF1 Data B1 and B2 Registers to the
selected Trigger Memory word or vice versa.

Message Valid 1 Register

(addresses 0xB1 & 0xB0)

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

MsgVal16-9

MsgVal8-1

Message Valid 2 Register

(addresses 0xB3 & 0xB2)

MsgVal32-25

MsgVal24-17

r

r

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Rd/Wr

res

res

res

res

res

res

res

res

res

res

Trigger Number

rw

r

r

r

r

r

r

r

r

r

r

rw

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

IF1 Message Data B1

Type

Message Number

res

Cycle_Code

IF1 Message Data B2

Time_Mark

rw

rw

Advertising