NOTE IN USING THE UNIT AS A

MULTI-SYSTEM

With a multi system air conditioner, multiple in-

door units can connect to one outdoor unit.
With a multi system air conditioner, you can not

operate different indoor units in different mode.
• If one unit is operating in COOL (or DRY)

mode, the other units are to be operated in

the same mode. The mode of the indoor unit

which operates fi rst is given priority. The in-

door unit turned on later in different mode can

not start operation. It starts to beep and the

OPERATION lamp and TIMER lamp starts to

blink. In this case, set all the indoor units to

the same operation mode.

• COOL mode and DRY mode can be set at the

same time.

NOTES ON OPERATION

OPERATING CONDITION

Cooling

Indoor temperature

Outdoor temperature

Single

Multi

upper limit

32°C

46°C

43°C

lower limit

21°C

-10°C

21°C

Heating

Indoor temperature

Outdoor temperature

upper limit

27°C

24°C

lower limit

-

-15°C

• The built-in protective device may prevent the

unit from operating when used at higher tem-

perature than this range.

• Condensation may form on the air outlet if the

unit operates continuously in the COOL or

DRY mode when humidity is over 80 %.

NOTE ON HEATING OPERATION

DEFROSTING FUNCTION

• When frost forms on the outdoor unit during

heating operation, the unit operate automatic

defrosting for about 5 to 10 minutes to remove

the frost. During defrosting, the indoor and out-

door fans stop operating.

HEATING EFFICIENCY

• The unit employs a heat pump that draws

heat from the outside air and releases it into

the room. The outside temperature therefore

greatly affects the heating effi ciency.

• If the heating effi ciency is reduced due to low

outside temperature, use an additional heater.

• It takes time to warm up and heat the entire

room because of the forced air circulation sys-

tem.

WHEN POWER FAILURE OCCURS

• This air conditioner has a memory function to

store settings when a power failure occurs.

After power recovery, the unit will automati-

cally re-start in the same settings which were

active before the power failure, except for

timer and FULL POWER settings.

• If a power failure occurs while the timer is set,

the timer setting will be cancelled and will not

be retrieved even after the power is restored.