BEFORE CALLING FOR SERVICE

The malfunctions shown in the left-hand column below, labeled “Fault”, do not necessarily indicate functional
faults of the machine. It is therefore advisable to refer to “Checking” shown in the right-hand column before
calling for service.

Fault

Checking

(1) The display shows symbols that do not make

sense.

• Has the machine been initialized properly as

shown in “PREPARING THE CASH REGISTER”?

(Note that initialization clears all the data and

programmed settings stored in memory.)

(2) The display won’t illuminate even when the

mode switch is turned to any other position than

“ ”.

• Is power supplied to the electrical outlet?

• Is the AC adapter plug out or loosely connected to

the AC outlet?

(3) The display is illuminated, but the whole

machine refuses registrations.

• Is the mode switch set properly at the “REG”

position?

(4) No receipt is issued.

• Is the paper roll properly installed?

• Is there a paper jam?

• Is the receipt function in the “OFF” status?

• Is the print roller arm securely locked?

(5) Printing is unusual.

• Is the print roller arm securely locked? Open the

print roller arm, and lock the arm by following the

instruction of installation.

• Is the paper roll properly installed?

• Are the printer head/sensor/roller clean?

(6) Continuous printing stops.

• “–” will be displayed in order from left to right

continuously. It occurs when the printer

temperature is high.

Printing will automatically restart after several

seconds.

Error code table

When the following error codes are displayed, press the

l

key and take a proper action according to the table

below.

Error

code

Error status

Action

E01

Registration error

Make a correct key entry.

E02

Misoperation error

Make a correct key entry.

E11

Compulsory depression of the

s

key

Press the

s

key and continue the operation.

E12

Compulsory tendering

Make a tendering operation.

E33

Compulsory SCM (starting cash memory)
entry

Make the SCM (starting cash memory) entry.

E34

Overflow limitation error

Make a registration within a limit of entry.

E35

The open price entry is inhibited.

Make a preset price entry.

E36

The preset price entry is inhibited.

Make an open price entry.

E37

The direct finalization is inhibited.

Make a tendering operation.

E67

Subtotal void is not allowed.

Finalize the transaction, and correct the wrong
entries in the

mode.

E80

The battery trouble is occurred.

Change the battery.

Advertising