Black Box LR5100A-T User Manual

Page 55

Advertising
background image

Applications

47

Configure Remote Site Profiles for Frame Relay with ISDN backup

Frame Relay operation is set-up as described in section 2.3.2

The PVC on both partner routers must be disabled during this set-up
procedure, then re-enabled when ready to start.

ISDN call set-up is done as described in section 2.3.1.

Recovery operation is set-up on the secondary activation menu.

If the ISDN circuit is to be available only at specified times, rather than all the

time (the default), set-up a recovery schedule with times the connection is to

be activated and deactivated

Activation Schedule

Location: Main

Ä

Configuration

Ä

WAN Set up

Ä

Remote Site Set-up

Ä

Edit Remote Site

Ä

Connection Set-up

Ä

Activation

Ä

Schedule

Enter “a” and the times the recovery circuit is to be made available, enter “d”

and the times the recovery circuit is to be deactivated.

Enable the secondary activation circuit for recovery

Recovery

Location: Main

Ä

Configuration

Ä

WAN Set

up

Ä

Remote Site Set-up

Ä

Edit Remote Site

Ä

Connection

Ä

Recovery

The recovery schedules MUST be set identically on both partner PPP routers
to operate; if they are not, one router will try to bring the link up and the other
will shut it down.

7

7

Advertising
This manual is related to the following products: