Interface Pinouts

84

RS442 & RS530 Link Pinouts

The connector shown here and pinouts described here correspond to the connector labeled

“RS530” on the back of the unit.

DB25 Female DTE

13

1

25

14

Contact
Number

Circuit

Circuit

Name

Direction

To From

DCE DCE

1

Shield

Protective Ground

NA

2

BA (A)

Transmitted Data

X

3

BB (A)

Received Data

X

4

CA (A)

Request to Send

X

5

CB (A)

Clear to Send

X

6

CC (A)

Data Set Ready

X

7

AB

Signal Ground

NA

8

CF (A)

Received Line Signal Detector

X

9

DD (B)

Receive Signal Element Timing (DCE Source)

X

10

CF (B)

Received Line Signal Detector

X

11

DA (B)

Transmit Signal Element Timing (DTE Source)

X

12

DB (B)

Transmit Signal Element Timing (DCE Source)

X

13

CB (B)

Clear to Send

X

14

BA (B)

Transmitted Data

X

15

DB (A)

Transmit Signal Element Timing (DCE Source)

X

16

BB (B)

Received Data

X

17

DD (A)

Receive Signal Element Timing (DCE Source)

X

18

LL

Local Loopback

X

19

CA (B)

Request to Send

X

20

CD (A)

Data Terminal Ready

X

21

RL

Remote Loopback

X

22

CC (B)

Data Set Ready

X

23

CD (B)

Data Terminal Ready

X

24

DA (A)

Transmit Signal Element Timing (DTE Source)

X

25

----------

Figure D-7 RS530 Link Pinouts

The connecting cable must be a shielded cable.

Circuits which are paired (contain an (A) and (B) reference) should be connected to

twisted pairs within the connecting cable.

Advertising