Warning, Caution, Troubleshooting – New Buck Corporation FP-BR-10-ZC User Manual

Page 30

Advertising
background image

TROUBLESHOOTING

WARNING

TURN OFF BURNER, UNPLUG HEATER AND LET COOL BEFORE
SERVICING. ONLY A QUALIFIED SERVICE PERSON SHOULD
SERVICE AND REPAIR HEATER.

CAUTION

NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN
ODS/PILOT. THIS CAN DAMAGE ODS/PILOT.

OBSERVED

PROBLEM


1. Igniter button is pressed,

no spark at ODS/Pilot
















2. Igniter button is pressed
Spark at ODS/Pilot
No Ignition


POSSIBLE

CAUSE


1. I g n i t e r e l e c t r o d e

positioned incorrectly.

2. Igniter electrode broken
3. Igniter electrode not con-

nected to igniter cable

4. Igniter cable pinched or

wet



5. Piezo igniter nut is loose




6. Broken igniter cable
7. Bad piezo igniter

1. Gas supply turned off or

manual shutoff valve is
closed

2. Control knob not in

“PILOT” position

3. Control knob not pressed

in while in “PILOT”
position

4. Air in gas lines when

installed


SOLUTION


1. Replace igniter

2. Replace igniter
3. Reconnect igniter cable

4. Free igniter cable if

pinched by any metal or
tubing. Keep igniter
cable dry.

5. Tighten nut holding

piezo igniter to heater
cabinet. Nut is located
inside heater cabinet at
top

6. Replace igniter cable
7. Replace piezo igniter

1. Turn on gas supply or

open manual shutoff
valve

2. Turn control knob to

“PILOT” position

3. Press in control knob

while in “PILOT”
position

4. Continue to hold down

control knob. Repeat
igniting operation until
air is removed.

Page 28