Table 4B — 619FNQ Physical Data

LEGEND

*See Table 3 for factory charge and additional field charge requirements.

SYSTEM SIZE

018

024

030

036

NOMINAL CAPACITY (Btuh)

Heat Pump

Cooling

17,900

22,600

29,200

33,400

Heating

16,800

20,800

27,400

32,400

Cooling with Electric Heat

17,000

22,600

29,000

36,000

SEER

13

HSPF

7.7

OPERATING WEIGHT (lb)

91

91

95

95

REFRIGERANT*

R-410A

Control (Cooling)

AccuRator Control

Control (Heating)

AccuRator Control

INDOOR FAN

Direct Drive Centrifugal

Rpm/Cfm High

440/690

440/690

660/910

660/910

Rpm/Cfm Medium

360/560

360/560

550/760

550/760

Rpm/Cfm Low

300/470

300/470

470/670

470/670

Motor Watts

110

110

210

210

Blowers Quantity...Size (in.)

1...18

INDOOR COIL

Copper Tube, Aluminum Fin

Face Area (sq ft)

4.8

4.8

4.6

4.6

No. of Rows

2

2

3

3

Fins/in.

18

18

18

18

Circuits

6

6

10

10

FILTERS

Cleanable

Quantity...Size (in.)

1...24 x 23

5

/

16

AIRSWEEP

Horizontal

Auto/Preset

OPERATING LIMITS

Heating (Min/Max)

15 F/75 F

Cooling (Min/Max)

55 F/125 F

CONTROLS

Integrated Microprocessor

Remote Controller Options

Wireless CRC

Diagnostics

Yes

Defrost Method

Demand Defrost

Timer Mode

Yes

Warm Start Feature

Yes

Test Mode

Yes

Freeze Protection

Yes

Dehumidification Mode

Yes

Fan Mode

High/Medium/Low/Auto

Auto Changeover

Yes

Auto Restart

Yes

Control Voltage

24

System Voltage

208/230

REFRIGERANT LINES

Connection Type

Flare

Flare

Flare

Flare

Mixed-Phase Line (in.) OD

3

/

8

3

/

8

3

/

8

3

/

8

Vapor Line (in.) OD

5

/

8

5

/

8

3

/

4

3

/

4

Max Length (ft)

200

200

200

200

Max Lift (Fan Coil Above) (ft)

60

60

60

60

Max Lift (Fan Coil Below) (ft)

60

60

60

60

CONDENSATE DRAIN SIZE (in.)

1

1

1

1

CRC