10. CONNECT WIRING

Connect cable into wiring box using provided wire connectors.

Connect wires as follow: BLACK to BLACK, WHITE to WHITE and GREEN
or BARE wire under ground screw. DO NOT FORGET TO CONNECT THE
GROUND
. Reinstall wiring cover.

WARNING

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all
applicable codes and standards. Before connecting wires, switch power off at service panel and lock
service disconnecting means to prevent power from being switched on accidentally.

!

HE0059

Position the power pack below the installed custom hood. Insert the house wiring cable through the wire clamp previously
installed in step 8. Tighten the wire clamp to secure the cable.

11. REMOVE THE BLOWER(S)

In order to ease the power pack alignment with existing ductwork, unplug and disassemble the blower(s) from the power pack
before installing the custom hood.

HE0085

Unplug the blower(s).

HD0282

R

IGHT

S

IDE

M

OUNTING

S

CREW

L

OCATION

Using a 5/16” socket, remove all blower
mounting screws from the inner top of the
power pack. Set aside the screws.

HD0269

L

EFT

S

IDE

M

OUNTING

S

CREW

L

OCATION

Slide the blower to disengage its flange
from the retaining bracket. Set aside the
blower.

HD0270

CP35 M

ODELS