Determining the status of a system fabric module

4

Determining the status of a system fabric module

At least one functional switch fabric module (SFM) must be plugged into slots S1 or S2 (the “control
plane slots”). If there are no functional SFMs in either slot during bootup, bootup is halted with a
message indicating that condition.

In an operational chassis, if all SFMs in the control plane slots become faulty or are removed, then
all the line cards will be faulted with a reason code that indicates no availability of an SFM. An
external raslog message will also be displayed.

Complete the following steps to determine the status of an SFM.

1. Check the LED indicators on the SFM (refer to

Figure 8

). The LED patterns may temporarily

change during POST and other diagnostic tests. For information about how to interpret the LED
patterns, refer to

Table 11

.

2. You can use the show sfm command or the show slots command to see whether the SFM is

enabled.

Figure 8

identifies the switch fabric module.

FIGURE 8

Switch fabric module

Active

Steady blue

Module is the active

MM

.

No action required.

No light (LED is off)

Module is booting up,
negotiating to be the active
MM, or is the standby MM.

No action required.

Ethernet
management
link (upper
left)

Steady green

Ethernet link speed is
10/100/1000 Mbps.

No action required.

No light (LED is off)

There is no link.

No action required.

Ethernet
management
link activity
(upper right)

Blinking green

Ethernet link is healthy and
traffic is flowing through port.

No action required.

No light (LED is off)

No traffic is flowing.

No action required.

TABLE 10

Management module LED descriptions (Continued)

LED purpose

Color

Status

Recommended action