10fitting the upper soft stop mechanism, 11aligning the doors, 4insertion into a row of kitchen units – Liebherr CBNPgb 3956 Premium BioFresh NoFrost User Manual

Page 9: Putting into operation, 4 insertion into a row of kitchen units

Advertising
background image

4.3.10 Fitting the upper soft stop mechanism

Fig. 15

u

Remove the cover

Fig. 15 (9)

from the faceplate

Fig. 15 (1)

and re-insert it at the other side.

u

Engage the upper soft stop unit with the joint on the hinge

side (A) and swivel into place (B).

w

The screw holes at the left and right have to register.

u

Screw the soft stop unit firmly into place(2 mal Torx® 15)

Fig. 15 (7)

.

Note

u

Keep to the correct order. First attach the panel over the soft

stop bracket, then the cover.

Fig. 16

u

Attach the faceplate

Fig. 16 (1)

to the soft stop bracket

Fig. 16 (4)

so that the catches face inwards and the front

faces the appliance.

u

Slide on the cover

Fig. 16 (5)

from the outside (A) and swivel

it over the bearing part

Fig. 16 (8)

(B).

u

Attach the cover

Fig. 16 (5)

and engage it as far as the first

detent.

w

The openings for the pin are on top of one another after the

soft stop bracket has been positioned.

u

Draw the soft stop bracket

Fig. 16 (4)

towards the bearing

part and insert the pin

Fig. 16 (3)

from above so that the

square sits in the recess.

u

Now completely snap the cover

Fig. 16 (5)

onto the bearing

part

Fig. 16 (8)

.

w

Pay attention that the cover fits properly so that the door

closes properly and the pin is secured.

u

Twist the safety lock

Fig. 16 (2)

for removal.

u

Slide the faceplate

Fig. 16 (1)

onto the door and snap it into

place.

u

Turn the cover

Fig. 6 (6)

through 180°, attach and engage it

on the handle side.

4.3.11 Aligning the doors

u

If necessary, align the doors to the appliance housing by

way of the oblong holes in the bottom turn hinge

Fig. 12 (43)

and middle turn hinge

Fig. 11 (31)

. To do so, unscrew the

middle screw in the bottom turn hinge

Fig. 12 (43)

.

WARNING

Risk of injury due to the door dropping out!

If the bearing parts are not screwed into place firmly enough,

the door may drop out. This may lead to severe injuries. What

is more, the door may not close and therefore the appliance

may fail to cool properly.

u

Screw the turn hinges firmly into place with 4 Nm.

u

Check all of the screws and retighten if necessary.

4.4 Insertion into a row of kitchen units

Fig. 17

(1) Stack cabinet

(3) Kitchen cabinet

(2) Appliance

(4) Wall

x

For appliances supplied with wall spacers, the measurement

increases by 35 mm (see 4.2) .
The appliance can be inserted into a row of kitchen units. To

match the appliance

Fig. 17 (2)

to the height of the row of units,

a suitable stack cabinet

Fig. 17 (1)

can be fitted above the

appliance.
When inserting the appliance into a row of kitchen units (max.

depth 580 mm), the appliance can be installed directly next to

the kitchen unit

Fig. 17 (3)

. The appliance door projects

70 mm

x

relative to the front of the kitchen units.

Ventilation requirements:

-

At the back of the stack cabinet there has to be a ventilation

duct of at least 50 mm depth throughout the width of the

stack cabinet.

-

The ventilation space under the ceiling has to be at least

300 cm

2

.

-

the larger the ventilation space, the more energy-saving the

appliance is in operation.

If the appliance is installed with the hinges next to a wall

Fig. 17 (4)

, the distance between appliance and wall has to be

at least 40 mm.

Putting into operation

* Depending on model and options

9