Bryant 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE 352AAV User Manual

Page 9

Advertising
background image

—9—

352AAV

MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITH AND WITHOUT INSULATION

IN WINTER DESIGN TEMPERATURE AMBIENT

*

* Pipe length (ft) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total

allowable pipe length as specified in Table 6.

† Insulation thickness based on R value of 3.5 per inch.

UNIT SIZE

WINTER DESIGN

TEMPERATURE

(°F)

MAX PIPE

DIAMETER

(IN.)

WITHOUT

INSULATION

WITH 3/8-IN. OR

THICKER INSULATION†

060

20

2

44

70

0

2

21

70

–20

2

20

57

080

20

2

55

55

0

2

30

55

–20

2

16

55

20

2.5

58

70

0

2.5

29

70

–20

2.5

14

67

100

20

2.5

40

40

0

2.5

38

40

–20

2.5

21

40

20

3

63

70

0

3

30

70

–20

3

12

70

120

20

3

70

70

0

3

38

70

–20

3

19

70

20

4

65

70

0

4

26

70

–20

4

5

65